SR Series Statistical Multiplexer, 24 Port
$2,155.00
In stock
Description
DESCRIPTION
All port parameters are set with an asynchronous terminal (or PC) connected to the network management port or port 1. Set-up procedures are menu driven and fully explained on screen. All configuration parameters are maintained through power outages.
The asynchronous ports can be individually set for speeds to 38.4 Kbps (57.6 Kbps on the SR-04). Hardware (CTS/Busy high or low) or software (Xon/Xoff even, odd, mark, space or transparent) flow control is also set on a port by port basis.
The SR multiplexer composite is synchronous or asynchronous full duplex lines either analog or digital. The composite can be run at speeds up to 128 Kbps sync, 115.2 Kbps async.
The network management port includes local and remote configuration commands. The Show Configuration Commands allow the system manager to view the configuration settings of both the local and remote SR Multiplexers. Network management features include port and composite loopbacks, capture of a remote or local port, send a test message to an individual local or remote port, set multiplexer ID for node identification and a built-in “data line monitor” which allows the monitoring of the transmit or receive lines at the local multiplexer. A unique feature of the SR multiplexers is the Copy Command. This command allows a trainer at the host site to “copy” any local or remote port to view exactly what the user is entering. This feature can save thousands of training dollars by eliminating travel expenses.
The SR multiplexer has a side panel access for firmware cartridge installation. This feature simplifies installation of upgrades for new features and functions.
The SR multiplexers are compatible with virtually all async protocols for machine-to-machine or host computer-to-remote links. In addition, with features like the loopback, test message, ID, monitor and copy commands, you can take charge of your network like never before.
The single port SR multiplexer is quite useful for multi-drop and multi-point applications such as point-of-sale terminals, SCADA, and other machine control applications.
The internal modem is available in a V.90 version. With the internal modem, multiplexer management commands provide direct access to the modem, and provide a command string to be sent to the modem after every power on. These units can also be configured for the “one-touch” operation, whereby a link is dialed up by simply touching the space bar on ANY terminal connected to the multiplexer. The modem initialization command insures reliable modem operation. Using the internal modem removes many of the dial-up problems cause by unknown bargin-store quality modems.
SPECIFICATIONS
General
Asynchronous Statistical Multiplexing
1, 4, 8, 16, 24 or 32 channels
All ports can be 38,400 bps
Port Specifications
Data Format
1 Start bit
8 Data bits including parity if used
1 Stop bit
10 Bits totalRates: 300, 1200, 1800, 2400, 4800, 9600, 19200, 38400, (57600 on the SR-04) bps individually selectable per port
Interface: CCITT V.24, RS-232-D
Connectors: RJ-45 (8-wire)
Buffering: 64K dynamically allocated
Port Flow Control: Set on an individual port basisXon/Xoff
Clear to Send
Busy High
Busy Low
Network Specifications
Rates: Follows modem clock signals to 128 Kbps synchronous, 115.2 Kbps asynchronous
Interface: CCITT V.24, RS-232-D
Connector: RJ-45 (8-wire)
Error Correction: Automatic retransmission
Network to modem/DSU cable included
Operating Modes
Normal on-line multiplexing
“One Touch Dial” mode
Network loopback
Indicators (front panel)
Power, Multiplexing, Receive Error, Modem Ready, Option, Port 1 Setup, Loopback
Network Management Port
Interface: CCITT V.24, RS-232-D
Connector: RJ-45 (8-wire)
Can be mapped to Port 1
Network Management Port to terminal cable included
Network Management Port Commands
Help Screen
Remote Test Loop
Monitor Transmit
Monitor Receive
Network Loopback
Flow Control Active
Set TimeLOCAL & REMOTE:
Show Configuration
Show Network
Configure Ports
Configure Network
Port Loopback
Device Type
Reset
Capture Port
Copy Port
Send Test Message
Activity Counters
Physical/Electrical
Power requirements: 120 VAC, 30-43 Watts, .25-.36 Amps (Optional 12, 24, or 48 Vdc Power supplies available)
101/4″ x 93/4″ x 21/4″ (8 or 16 channels)
101/4″ x 93/4″ x 41/2″ (24 or 32 channels)
Temperature: Operating Temperature: -40 to +75C
Options
- V.90 internal modem
- 9600 bps V.29 4-wire internal modem
- 56 Kbps internal DSU/CSU
APPLICATION
How to Order
HOST or REMOTE:
SR-04 | 4 Port Host or Remote Multiplexer | $ 695 |
SR-01 | 1 Port Asynchronous FRAD | $ 450 |
SR-01/DSU | 1 Port Asynchronous FRAD with built-in 56Kbps DSU | $ 550 |
SR-08 | 8 Port Host or Remote Multiplexer | $ 1,195 |
SR-16 | 16 Port Host or Remote Multiplexer | $ 2,295 |
SR-24 | 24 Port Host or Remote Multiplexer | $ 3,495 |
SR-32 | 32 Port Host or Remote Multiplexer | $ 4,695 |
SR-V90 | V.90 Internal Modem | $ 350 |
SR-08-EC | 8 Port expansion kit | $ 1,200 |
SR-FR | Frame Relay firmware (Free when ordered with unit) |
$ 500 |
SR-DSU04 | Integral 64Kbps DSU/CSU for SR-04 | $ 300 |
SR-DSU | Integral 56Kbps DSU/CSU (for 8 to 24 port units only) |
$ 300 |
RK-8/16 | Rack mount for 8/16 port unit | $ 49 |
RK-24/32 | Rack mount for 24/32 port unit | $ 59 |
Additional information
Weight | 2 lbs |
---|---|
Dimensions | 5 × 5 × 5 in |